Corrosion risk of RC buildings after ten years the 2004 tsunami in Banda Aceh-Indonesia

机译:在Banda Aceh-Indonesia的2004年海啸之后,RC建筑物的腐蚀风险

获取原文

摘要

Banda Aceh was struck by the 2004 tsunami and submerged by seawater almost half a day and covered by mud monthly. The effect of the tsunami inundation for reinforce concrete (RC) buildings was the buildings become more susceptible to corrosion due to ion chloride intrusion. Hence, early failure might happen to the buildings because of rebar corrosion. It can be worsening by the earthquakes that frequently occur in the region. Thus, the corrosion monitoring for the buildings become important. The previous monitoring was taken on 2009 and 2012 and found that the corrosion level of the buildings already at intermediate to high risk. The objective of this study is to conduct corrosion risk monitoring for RC building after ten year the 2004 tsunami in Banda Aceh city, Indonesia. The monitoring was conducted using half-cell potential mapping technique that refers to ASTM C876 and performed in 2015. Three building in tsunami-affected area were chosen for the monitoring. The monitoring results show that the corrosion levels for the buildings located in the 2004 tsunami-affected area were at intermediate to high risk. Comparing the results with those on 2009 and 2012 indicated that the corrosion risk level tend to increase. Therefore, the regular monitoring and repairing are important to be carried out in order to hinder sudden failure of the buildings.
机译:Banda Aceh被2004年海啸袭击,海水淹没了近半天,并每月覆盖泥浆。海啸淹没对钢筋混凝土(RC)建筑的影响是由于离子氯化物侵入而变得更容易腐蚀。因此,由于钢筋腐蚀,建筑物可能会发生早期失败。在该地区经常发生的地震可能会恶化。因此,建筑物的腐蚀监测变得重要。以前的监测于2009年和2012年拍摄,发现建筑物的腐蚀水平已经处于中间的高风险。本研究的目的是在印度尼西亚班达市2004海啸之后对RC建设进行腐蚀风险监测。使用半电池潜在映射技术进行监测,该技术指的是ASTM C876并于2015年进行。选择海啸影响地区的三栋建筑物进行监测。监测结果表明,位于2004年海啸影响地区的建筑物的腐蚀水平均为高风险。将结果与2009年和2012年的结果进行比较表明腐蚀风险水平趋于增加。因此,定期监测和修复是重要的,以便妨碍建筑物的突然失败。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号