High-voltage electrical power transmission is an important development direction to improve the capacity of power transmission. However, the electromagnetic environmental problems caused by High voltage have been of concern, and corona is an important factor to influence on electromagnetic environment around transmission line. In this paper, based on the charge simulation method, and space charge effecting on line face charge distribution, the computation method of electric field intensity of the high-voltage transmission lines taking the corona discharge into account was established. With this model, ground level electrical field under 1000 kV UHV transmission lines was calculated; the result showed the impact of corona discharge on ground level electrical field distribution characteristics, the maximum electric field intensity appears on a distance of about 23 m to the middle phase line in horizontal position on the ground, the corona discharge could strengthen composed ground level electric field of transmission lines, and the greatest influences of corona on ground level electrical field could be below the middle phase line.
机译:高压电力传输是提高动力传动能力的重要发展方向。然而,由高电压引起的电磁环境问题是关注的,并且电晕是对传输线周围电磁环境影响的重要因素。本文基于电荷仿真方法,以及对线面电荷分布的空间电荷,建立了考虑电晕放电的高压传输线的电场强度的计算方法。通过该模型,计算了1000 kV UHV传输线下的地面电场;结果表明,电晕放电对地面电场分布特性的影响,最大电场强度出现在地面水平位置约23米到中间相线的距离上,电晕放电可以加强地面电平传输线的领域,电晕电视在地面电场上最大的影响可能低于中间阶段线。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号