首页> 外文会议>International Conference on Sustainable Energy, Environment and Information Engineering >Rapping Strategy and Electric Field Characteristics of ESP in a Power Plant
【24h】

Rapping Strategy and Electric Field Characteristics of ESP in a Power Plant

机译:在发电厂中的ESP策略和电场特征

获取原文

摘要

The electric field operating and rapping parameters of 1# Electrostatic Precipitators (ESP) had been monitored and analysed in a thermal power company. There were five electric fields in the ESP. The rapping time of 1# ESP was 150 seconds. The time interval when the rapping was stopped increased sequentially from the first to the fifth electrical field, and the neighbouring two electric fields did not overlap each other. The operating voltage in 1# ESP also went up sequentially from the first to the fifth electrical field. The secondary voltage and current of each electric field was closely related to the rapping interval. The total energy consumption was suggested to be 26.6-29 kW to keep the dust emission under 20 mg/Nm~3.
机译:在热电公司中监测和分析了1#静电除尘器(ESP)的电场操作和敲击参数。 ESP中有五个电场。敲击时间为1#ESP为150秒。当敲击的时间间隔从第一到第五电场顺序地停止增加,并且相邻的两个电场彼此不重叠。 1#ESP中的工作电压也从第一到第五电场顺序上升。每个电场的二次电压和电流与敲击间隔密切相关。建议总能耗为26.6-29千瓦,以保持20毫克/纳米〜3以下的粉尘排放。