首页> 外文会议>World Congress on Biosensors >Helix Channel Microfluidic Electrophoresis Chip Drove by Low Voltage
【24h】

Helix Channel Microfluidic Electrophoresis Chip Drove by Low Voltage

机译:螺旋通道微流体电泳芯片驱动低电压

获取原文

摘要

The conventional microfluidic electrophoresis chip must be applied higher voltage, which limited the microminiaturization and integration. According to the principle of electrophoresis chip, a helix channel electrophoresis chip drove by low voltage was proposed. Some key techniques were researched, which include the bubble issue, optimization of the chip structure, low cost hydrophilic surface modification for the chip, design of miniaturized control and detection system. Test results shown the helix channel chip has better separation than the cross channel chip, and the sample can be successfully separated below 100V voltage.
机译:必须施加常规的微流体电泳芯片较高的电压,这限制了微纯粹化和整合。根据电泳芯片的原理,提出了一种通过低电压推动螺旋通道电泳芯片。研究了一些关键技术,包括泡沫问题,优化芯片结构,低成本的芯片亲水表面改性,小型化控制和检测系统的设计。测试结果显示,螺旋通道芯片具有比交叉通道芯片更好的分离,并且样品可以成功分离在100V电压以下。