首页> 外文会议>Building Performance Simulation Conference >The importance of a fan location in the front Door in measuring of the air permeability by the Blower Door Test
【24h】

The importance of a fan location in the front Door in measuring of the air permeability by the Blower Door Test

机译:鼓风机门测试测量透气性的前门风扇位置的重要性

获取原文

摘要

The value of air permeability or the value of n50 provides important information about the impermeability of the building envelope and thus the quality of internal environment of the building. It is also one of the main evaluation criteria in classifying energy efficient buildings. Air permeability is determined by Blower Door Test where the fan blows air in or out from the measured area. The measurement is performed in a overpressure and afterwards in a under-pressure during which the leaks are detected. The frame is usually placed into the front door which themselves is a link part in the building envelope and thus the rate of leakage completely denies. The effect of leakage of the front door is so significant that it can often cause a misclassification of the energy efficient buildings. We have tested this hypothesis by Blower Door Test on a passive timber construction build in 2007 during which we have measured the object in position of measuring device placed in the front door and the balcony door that are not encumbered by leaks caused by a security hardware and by other specific elements.
机译:透气性的值或N50的值提供了有关建筑信封的不可渗透性的重要信息,从而提供了建筑物内部环境的质量。它也是分类节能建筑的主要评估标准之一。透气性由鼓风机门测试确定,其中风扇从测量区域中吹入空气中或出来。测量在超压和之后在欠压期间检测到的欠压。框架通常被放入前门,本身是建筑包络中的连杆部分,因此泄漏速率完全否定。前门泄漏的效果如此重要的是,它通常会导致节能建筑物的错误分类。我们在2007年的无源木材建筑构建上通过鼓风机门测试测试了这一假设,在此期间我们已经测量了放置在前门中的测量装置的位置和阳台门的位置,这些物体不会被安全硬件引起的泄漏阻碍通过其他特定的元素。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号