The 2005 Seismic Provisions for Structural Steel Buildings require the structural design drawings to“show the work to be preformed”and presents a list of items required for the seismic load resisting system.The use of the list requires a knowledge of the connection requirements in the Provisions for the various seismic load resisting systems along with the requirements in Appendix Q–Quality Assurance and Appendix W–Welding Provisions. Other requirements for the seismic load resisting system connections are found in ANSI/AWS D1.8 and ANSI/ AISC FEMA 358-05. This paper will review these design drawing requirements and point out where they can found in these documents.
机译:2005年《钢结构建筑抗震规定》要求结构设计图“显示待完成的工作”,并列出抗震系统所需的项目清单。使用该清单需要了解连接系统中的连接要求。各种抗震载荷系统的规定,以及附录Q –质量保证和附录W –焊接规定中的要求。有关抗地震载荷系统连接的其他要求,请参见ANSI / AWS D1.8和ANSI / AISC FEMA 358-05。本文将回顾这些设计图纸要求,并指出在这些文档中可以找到它们的位置。