首页> 外文会议>Proceedings of building simulation'95: proceedings of fourth IBPSA conference and exhibition >MULTIZONE MODELING OF THREE RESIDENTIAL INDOOR AIR QUALITY CONTROL OPTIONS
【24h】

MULTIZONE MODELING OF THREE RESIDENTIAL INDOOR AIR QUALITY CONTROL OPTIONS

机译:三种住宅室内空气质量控制方案的多区域建模

获取原文
获取原文并翻译 | 示例

摘要

The impact of central forced-air heating and coolingrnsystem modifications on the levels of selectedrnpollutants in single-family houses was evaluated byrnsimulating pollutant concentrations due to a variety ofrnsources in eight houses with typical HVAC systems.rnSimulations were performed with a multizone airflowrnand pollutant transport model and were repeated withrnthe systems modified to include an electrostaticrnparticulate filter, a heat recovery ventilator, and anrnoutdoor air intake damper. The system modificationsrnreduced the pollutant levels in the houses for somerncases; however, the results also demonstrated potentialrnlimitations in both the simulation method and thernperformance of the devices.
机译:通过模拟八座典型暖通空调系统房屋中各种来源的污染物浓度,评估了中央强制空气加热和冷却系统改造对单户住宅中选定污染物水平的影响。模拟采用多区域气流和污染物迁移模型进行,对系统进行了重复改造,修改后的系统包括静电微粒过滤器,热回收通风机和室外进气风门。该系统的修改降低了房屋中某些情况下的污染物水平;但是,结果也证明了仿真方法和设备性能的潜在局限性。