Using research that is now several decades old, the current Canadian masonry design standard, CSA S304.1-04, prescribes values for masonry design compressive strength based on the compressive strength of the concrete masonry unit and the type of mortar used in construction. The quality of unit production, masonry construction methods, and the theoretical understanding of masonry behaviour have improved significantly since these values were developed. As a consequence, current CSA S304.1-04 correlations between unit and masonry compressive strength values no longer reflect modern masonry construction and have been shown to be too conservative.;In this investigation, 140 concrete masonry prisms were constructed for compression testing to recalibrate the tabulated unit strength values. An update to CSA S304.1-04 is proposed which includes strength increases of 33-40% for prisms with type N mortar, 10-30% strength increases for prisms with type S mortar and low unit strength, and 0-12% decreases with high unit strength.
机译:根据数十年来的研究,当前的加拿大砌体设计标准CSA S304.1-04根据混凝土砌体单元的抗压强度和建筑中所用砂浆的类型,规定了砌体设计抗压强度的值。自从开发了这些值以来,单位生产的质量,砖石构造方法以及对砖石行为的理论理解有了显着提高。结果,当前的CSA S304.1-04单位和砌体抗压强度值之间的相关性不再反映现代砌体的构造,并且显示过于保守。在此调查中,建造了140个混凝土砌体棱镜用于压缩测试以重新校准。列表的单位强度值。提议对CSA S304.1-04进行更新,其中包括将N型砂浆的棱镜的强度提高33-40%,将S型砂浆且单位强度较低的棱镜的强度提高10-30%,并降低0-12%具有较高的单位强度。

著录项

  • 作者

    Ross, Michael David.;

  • 作者单位

    University of Alberta (Canada).;

  • 授予单位 University of Alberta (Canada).;
  • 学科 Engineering Civil.
  • 学位 M.S.
  • 年度 2013
  • 页码 97 p.
  • 总页数 97
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 老年病学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号