首页> 中文期刊> 《当代化工》 >结肠透析液(B液)中钾含量测定方法的比较研究

结肠透析液(B液)中钾含量测定方法的比较研究

         

摘要

建立结肠透析液(B 液)中钾含量测定方法。采用银量法(法定方法)、四苯硼钠-季胺盐法、四苯硼钠-容量法、紫外-紫外导数光谱法、原子吸收分光光度法(FAAS)及电感耦合等离子体发射光谱法(ICP-AES)测定结肠透析液(B 液)中钾的含量,并对六种方法的精密度、线性范围及检出限、加标回收率等做了比较。6种方法测定结果与法定法(银量法)结果一致,误差在允许范围内。FAAS 法是测定结肠透析液中钾含量的较优方法。%Potassium content in colon dialysis solution(B solution) was respectively determined by six methods including argentometry method,sodium tetraphenylborate gravimetric method,sodium tetraphenylborate volumetric method,derivative spectrophotometry method,alame atomic absorption spectrophotometry method(FAAS) and inductively coupled plasma-atomic emission spectrometry method(ICP-AES).And precision,linearity range,detection limit and standard recovery rate of the six methods were compared. The results show that the determination result of the six methods is in accord with that of statutory law (argentometry method); their errors are in allowable range;FAAS method is the best method for determining potassium content in colon dialysis solution.

著录项

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号