为优化对钢筋混凝土结构中钢筋的保护,设计了1套基于微胶囊的智能缓蚀系统(其中的微胶囊以乙基纤维素为囊壁,分别以单氟磷酸钠和亚硝酸钠为囊芯)并就其缓蚀性能进行了研究.利用XCT(X射线层析成像)技术进行钢筋锈蚀过程跟踪测试并对微胶囊的缓蚀效果进行了分析.结果表明:混凝土智能缓蚀系统对其中的钢筋起到了显著保护作用,缓蚀效果明显;在干湿循环试验中,相较于空白样,亚硝酸钠系统和单氟磷酸钠系统中的钢筋起锈时间分别延缓648,216 h,开裂时间相应延缓432,144 h;在干湿循环648 h后,亚硝酸钠系统和单氟磷酸钠系统中的钢筋锈蚀率分别为1.93%,3.06%,均明显低于空白样(锈蚀率为10.46%).%In order to optimize the protection of reinforcing bar in concrete structure,the smart systems,including the sodium nitrite(NaNO2)/ethyl cellulose(EC) microcapsule system and the sodium monofluorophosphate(MFP)/ethyl cellulose(EC) microcapsule system,were designed and studied.XCT(X-ray computed microtomography) testing technology was used to trace the corrosion process and introduced to test the corrosion inhibition effect.The results show that the smart system has a very significant corrosion inhibition performance.Compared with the blank group in wet-dry cycle tests,sodium nitrite system and sodium monofluorophosphate system significantly delay initial corrosion period for 648 and 216 h,and the initial cracking period is also prolonged for 432 and 144 h,respectively.After 648 h of wet-dry cycle,the corrosion ratio of the sodium nitrite system is only 1.93%,and the sodium system is 3.06%,which is much lower than that of blank system's 10.46%.

著录项

  • 来源
    《建筑材料学报》 |2018年第1期|33-40|共8页
  • 作者单位

    中国地震局工程力学研究所地震工程与工程振动重点实验室,黑龙江哈尔滨150080;

    深圳大学广东省滨海土木工程耐久性重点实验室,广东深圳518060;

    深圳大学广东省滨海土木工程耐久性重点实验室,广东深圳518060;

    深圳大学广东省滨海土木工程耐久性重点实验室,广东深圳518060;

    深圳大学广东省滨海土木工程耐久性重点实验室,广东深圳518060;

    中国地震局工程力学研究所地震工程与工程振动重点实验室,黑龙江哈尔滨150080;

    深圳大学广东省滨海土木工程耐久性重点实验室,广东深圳518060;

  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类 非金属复合材料;
  • 关键词

    微胶囊; 钢筋; 缓蚀; X射线层析成像;

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号