首页> 中文期刊> 《无损检测》 >双线型像质计调制度的自动定量方法

双线型像质计调制度的自动定量方法

         

摘要

双线型像质计常用于测量射线检测图像的不清晰度,或测量数字射线探测器的基本空间分辨率。在实际应用中,用人工方法对双线型像质计调制度的定量计算比较繁琐。为解决这一问题,提出了一种双线型像质计调制度的自动定量方法。首先,将双线型像质计的灰度数据进行分段和归一化处理,并根据起始、终止点对应的灰度值进行数据甄别,决定是否进行下一步分析;然后,设计相应的算法寻找线对的沉降值,转换后即得到线对的调制度。所提出的自动定量方法,针对射线检测试验中的双线型像质计的灰度曲线进行一次处理,即可便捷、可靠地定量出各个线对的调制度。%Duplex wire image quality indicator (IQI)is often used to measure unsharpness in radiography,or to determine basic resolution of an X-ray digital detector.However,manual determination of modulation of the IQI is rather bothersome.So,an automatic method was put forward.Firstly,data from IQI was cut to segments by certain width from beginning to end,and each segment was normalized.All the segments were discriminated according to gray values of beginning position and end position,and qualified segments need to be processed further.Secondly, dip position in duplex wire curve was searched according to an algorithm,and its position value in the segmented curve can be used to determine the modulation.The proposed method is able to determine modulation of each duplex wire quickly and reliably through processing j ust a time.

著录项

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号