首页> 美国卫生研究院文献>Journal of Sports Science Medicine >Heart Rate Unreliability during Interval Training Recovery in Middle Distance Runners
【2h】

Heart Rate Unreliability during Interval Training Recovery in Middle Distance Runners

机译:中长跑运动员间歇训练恢复过程中的心率不可靠性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Heart rate (HR) was tested as a reliable index for recovery management during interval training (IT), considering its relationship with the several factors involved in respiratory, metabolic and cardiovascular homeostasis. Thirteen runners underwent two different IT sessions: at 80% and 120% of the second ventilatory threshold (VT2). Throughout both sessions HR, oxygen uptake (VO2), carbon dioxide production (VCO2) and pulmonary ventilation (VE), were measured by means of a portable gas analyzer. Carbon dioxide production excess (CO2excess), respiratory exchange ratio (RER), oxygen pulse (OP) and oxygen debt (O2debt) were also estimated. A significant increase in HR values (144 versus 150 beats·min−1 between the first recovery and the last, p < 0.001) was observed at 80% of the VT2 speed. At the over-threshold intensity, HR rose from 159 to 168 beats·min−1 from the first recovery to the last (p < 0.001). OP showed a declining trend from the first to the last recovery at 80% at the VT2 speed (18.3 versus 16.4 mL·beats−1, p < 0.05) and between the first and the last recovery in tests performed at 120% of the VT2 speed (17.8 versus 16.3 mL·beats−1, p < 0.05). No change occurred in CO2excess, VO2, RER, VE and O2debt. On the basis of our research, the use of fixed HR as a reliable index of the established recovery is inaccurate and unfit for training. The phenomenon of cardiac drift to set the restart timing after the repetitions, i.e. by progressively increasing HR values, should be taken into account by coaches.Key points class="unordered" style="list-style-type:disc">During an IT session, if recovery time after repetitions is fixed, HR supplies a different indication compared to all the respiratory parameters: HR indicates an incomplete recovery while the other parameters do not.The use of fixed HR values as a reliable index of the established recovery during IT is inaccurate and it may be the cause of under-training.To set the restart timing after repetitions the phenomenon of cardiac drift should be taken into account by coaches.HR drift during recoveries did not appear linked to the CO2excess.
机译:考虑到心率(HR)与呼吸,代谢和心血管稳态相关的几个因素之间的关系,将其作为间隔训练(IT)中恢复管理的可靠指标进行了测试。 13位跑步者分别进行了两次IT训练:第二次呼吸阈(VT2)的80%和120%。在这两个时段中,​​均使用便携式气体分析仪测量了HR,摄氧量(VO2),二氧化碳生成量(VCO2)和肺通气量(VE)。还估算了二氧化碳的过量生产(CO2过量),呼吸交换比(RER),氧气脉搏(OP)和氧气负担(O2负债)。在VT2速度的80%时,观察到第一次恢复和最后一次恢复之间的HR值显着增加(144对150次·min -1 ),p <0.001。在阈值以上的强度下,从第一次恢复到最后一次恢复,HR从159次/ min -1 上升到168次·min -1 (p <0.001)。在VT2速度下,OP从第一次恢复到最后一次恢复以80%的速度下降(18.3对16.4 mL·beats -1 ,p <0.05),并且在测试的第一次和最后一次恢复之间呈下降趋势。以VT2速度的120%进行运动(17.8对16.3 mL·beats -1 ,p <0.05)。二氧化碳过量,VO2,RER,VE和O2债务没有变化。根据我们的研究,使用固定的HR作为已建立的恢复的可靠指标是不准确的,不适合进行培训。教练应考虑在重复后设置心跳的现象,即通过逐渐增加HR值来确定重启时间。要点 class =“ unordered” style =“ list-style-type:disc”> <!-list-behavior =无序前缀= word-mark-type = disc max-label-size = 0-> 在IT会话期间,如果重复后的恢复时间是固定的,则HR将提供不同的指示所有呼吸参数:HR表示恢复不完全,而其他参数则不恢复。 使用固定的HR值作为IT期间确定的恢复的可靠指标是不准确的,这可能是导致 要设置重复后的重启时间,教练应考虑心脏漂移现象。 恢复过程中的HR漂移似乎与CO2过量无关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号