This study is to quantitatively evaluate the efficacy of using a non-contact automatic articulating paper dispenser for reducing microbial articulating paper contamination. Articulating papers in four-handed mode, non-four-handed mode, and via an automatic articulating paper dispenser were evaluated. An adenosine triphosphate bioluminescence assay was used to quantitatively measure the relative light unit (RLU) values of the rest unused articulating papers in the same package to detect contamination at 4 time points, and triplicate examinations were performed for all three methods. The RLUs were recorded, compared, and evaluated. For four-handed mode (n = 36), the RLUs at the four time points were 2.44, 32.89, 37.89, and 27.22, with a satisfactory rate of 94%. The RLUs for non-four-handed mode (n = 36) were 2.22, 286.44, 299.44, and 493.56, with a satisfactory rate of 36%. The RLUs for using the automatic dispenser (n = 36) were all 0 with a satisfactory rate of 100%. The satisfactory rates were significantly different among three methods. No significant differences were observed in the satisfactory rates for the four time points samples. Contact by gloved hands can cause severe biological contamination of articulating paper. However, by using standard four-handed mode or a non-contact automatic articulating paper dispenser, contamination can be controlled.
机译:这项研究旨在定量评估使用非接触式自动铰接纸分配器减少微生物铰接纸污染的功效。对四手模式,非四手模式的铰接纸以及通过自动铰接纸分配器的铰接纸进行了评估。使用三磷酸腺苷生物发光测定法定量测量同一包装中其余未使用的铰接纸的相对光单位(RLU)值,以在4个时间点检测污染,并对这三种方法进行了三次重复检查。记录,比较和评估RLU。对于四手模式(n = 36),四个时间点的RLU分别为2.44、32.89、37.89和27.22,满意率为94%。非四手模式(n = 36)的RLU为2.22、286.44、299.44和493.56,满意率为36%。使用自动分配器的RLU(n = 36)全部为0,满意率为100%。三种方法的满意率显着不同。四个时间点样本的满意率没有观察到显着差异。戴手套的手接触可能导致关节纸严重生物污染。但是,通过使用标准的四手模式或非接触式自动铰接式纸张分配器,可以控制污染。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号