Accurate measures of liver fat content are essential for investigating the role of hepatic steatosis in the pathophysiology of multiple metabolic disorders. No traditional imaging methods can accurately quantify liver fat content. [1H]-magnetic resonance spectroscopy (MRS) is restricted in large-scale studies because of the practical and technological issues. Previous attempts on computer-aided ultrasound quantification of liver fat content varied in method, and the ultrasound quantitative parameters measured from different ultrasound machines were hardly comparable. We aimed to establish and validate a simple and propagable method for quantitative assessment of liver fat content based on the combination of standardized ultrasound quantitative parameters, using [1H]-MRS as gold standard. Totally 127 participants were examined with both ultrasonography (US) and [1H]-MRS. Ultrasound hepatic/renal echo-intensity ratio (H/R) and ultrasound hepatic echo-intensity attenuation rate (HA) were obtained from ordinary ultrasound images using computer program. Both parameters were standardized using a tissue-mimicking phantom before analysis. Standardized ultrasound H/R and HA were positively correlated with the liver fat content by [1H]-MRS (r = 0.884, P < 0.001 and r = 0.711, P < 0.001, respectively). Linear regression analysis showed ultrasound H/R could modestly predict the amount of liver fat (adjusted explained variance 78.0%, P < 0.001). The addition of ultrasound HA slightly improved the adjusted explained variance to 79.8%. Difference of estimated liver fat contents between different ultrasound machines and operators was reasonably well. Thus, computer-aided US is a valid method to estimate liver fat content and can be applied extensively after standardization of ultrasound quantitative parameters.
机译:肝脂肪含量的准确测量对于调查肝脂肪变性在多种代谢性疾病的病理生理中的作用至关重要。没有传统的成像方法可以准确地量化肝脏脂肪含量。由于实际和技术问题,[ 1 H]磁共振波谱(MRS)在大规模研究中受到限制。先前对计算机辅助肝脂肪含量超声定量的尝试在方法上有所不同,并且从不同超声机器测量的超声定量参数几乎不可比。我们旨在建立和验证一种简单可行的方法,以标准化的超声定量参数为基础,以[ 1 H] -MRS为金标准,对肝脂肪含量进行定量评估。共有127名参与者接受了超声检查和[ 1 H] -MRS的检查。使用计算机程序从普通超声图像中获取超声肝/肾回声强度比(H / R)和超声肝回声强度衰减率(HA)。在分析之前,使用组织模仿体模将两个参数标准化。 [ 1 H] -MRS对标准超声H / R和HA与肝脂肪含量呈正相关(分别为r = 0.884,P <0.001和r = 0.711,P <0.001)。线性回归分析显示,超声H / R可以适度预测肝脂肪量(调整后的解释方差为78.0%,P <0.001)。超声HA的添加将调整后的解释方差略微提高至79.8%。在不同的超声机器和操作者之间,估计的肝脏脂肪含量之间的差异相当好。因此,计算机辅助US是评估肝脂肪含量的有效方法,并且在超声定量参数标准化后可以广泛应用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号