首页> 美国卫生研究院文献>Oxford Open >CONVERSION FACTOR FROM DOSEMETER READING TO AIR KERMA FOR NUCLEAR WORKER USING ANTHROPOMORPHIC PHANTOM FOR FURTHER CONVERSION FROM AIR KERMA TO ORGAN-ABSORBED DOSE
【2h】

CONVERSION FACTOR FROM DOSEMETER READING TO AIR KERMA FOR NUCLEAR WORKER USING ANTHROPOMORPHIC PHANTOM FOR FURTHER CONVERSION FROM AIR KERMA TO ORGAN-ABSORBED DOSE

机译:使用人机幻影从空气比释动能到有机吸收剂量的进一步转化从核素工作人员的剂量学读数到空气比释动能的转换因子

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Estimation of cancer risk based on the organ-absorbed dose is underway for the Japanese Epidemiological Study on Low-Dose Radiation Effects (J-EPISODE). The reconstruction method for the organ-absorbed dose follows the approach adopted in the IARC 15-Country Collaborative Study, which examined the dosemeter response to photon exposure for the old film badge (FB) type, a multi-element FB and a thermoluminescence dosemeter. Until 2000, the dosemeters used in Japan were almost the same in the IARC study, so IARC study data could be used as they were. However, since 2000, the type of dosemeter has been replaced with active personal dosemeters (hereafter called electronic personal dosemeters), radio-photoluminescent glass dosemeters (Glass badge) and optically stimulated luminescence dosemeters (Luminess badge). Hence, it was necessary to collect these data again. A dosemeter response experiment was conducted using a device that irradiated an anthropomorphic phantom in the Japan Atomic Energy Agency calibration laboratories. The aim of the paper is to provide a conversion factor from reading in terms of (10) to air kerma for realistic conditions for further conversion from air kerma to organ-absorbed dose. The obtained dosemeter responses for the dosemeter types currently used in Japan were consistent with those in the IARC study. These data will be utilized for J-EPISODE in reconstructing the organ-absorbed dose.
机译:日本的低剂量放射效应流行病学研究(J-EPISODE)正在进行基于器官吸收剂量的癌症风险评估。器官吸收剂量的重建方法遵循IARC 15国合作研究中采用的方法,该研究检查了旧膜徽章(FB)型,多元素FB和热致发光剂量计对光子暴露的剂量计响应。在2000年之前,日本使用的剂量计在IARC研究中几乎相同,因此可以直接使用IARC研究数据。但是,自2000年以来,剂量计的类型已被有源个人剂量计(以下称为电子个人剂量计),放射光致发光玻璃剂量计(Glass徽章)和光激发发光剂量计(Luminess徽章)取代。因此,有必要再次收集这些数据。在日本原子能机构校准实验室中,使用辐照拟人体模的设备进行了剂量计响应实验。本文的目的是为实际条件提供从读数(10)到空气比释动能的转换因子,以进一步从空气比释动能转换为器官吸收剂量。日本目前使用的剂量计类型获得的剂量计响应与IARC研究中的一致。这些数据将用于J-EPISODE重建器官吸收剂量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号