Four manufacturers provided laboratory airflow and power data as a function of external static pressure for 37 multispeed fan-coil units with permanent split capacitor motors. These data were used to develop an airflow performance model of fan-coil units that could be implemented in a building simulation program. The fan-coil units had fan motors ranging from 0.033 hp to 0.75 hp (25 W to 560 W) and maximum airflows that ranged from 242ft~3/min to 2646ft~3/min (0.11 m~3/s to 1.25 m~3/s). The model included normalized fan motor power and fan airflow at each speed setting. The normalized power versus normalized airflow data for the range of external static pressures typically plotted in a grouping of data at each speed setting. These average normalized powers and airflows were evaluated for each unit. The normalized values were combined with a linear fit to the high airflow and power curves to develop a straightforward process for generating airflow and power curves as a function of external static pressure. A procedure was developed to determine the intersection of the air system curve with the fan-coil airflow and power curves. The resulting model could be used to describe the airflow and power performance of a specific manufacturer's permanent split capacitor fan-coil unit over multiple speeds and external static pressures.
机译:四种制造商提供了实验室气流和功率数据,作为带有永久分离电容器电机的37个多飞行器风扇单元的外部静压的功能。这些数据用于开发风扇线圈单元的气流性能模型,其可以在建筑模拟程序中实现。风扇线圈单元的风扇电机范围为0.033 HP至0.75 HP(25 W至560 W),最大的气流范围为242英尺〜3 / min至2646英尺〜3 / min(0.11 m〜3 / s至1.25 m〜 3 / s)。该模型包括每个速度设定的归一化风扇电机电源和风扇气流。用于通常在每个速度设置的数据分组中绘制的外部静态压力范围的归一化功率与归一化气流数据。对每个单元评估这些平均归一化功率和气流。将归一化值与线性配合合并到高气流和功率曲线中,以开发出用于产生气流和功率曲线的直接过程,作为外部静压的函数。开发了一种程序以确定空气系统曲线与风扇线圈气流和功率曲线的交叉点。所产生的模型可用于描述特定制造商的永久分离电容器风扇单元的气流和功率性能在多个速度和外部静压压力下。

著录项

  • 来源
    《ASHRAE Transactions》 |2020年第2期|594-606|共13页
  • 作者

    Dennis L. ONeal; Peng Yin;

  • 作者单位

    School of Engineering and Computer Science at Baylor University Waco TX USA;

    Department of Mechanical Engineering at University of Louisiana at Lafayette Lafayette LA USA;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-18 21:40:47

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号