The bacteriostatic properties of carbon disul-phide (CS_2) hamper its biodegradation in conventional biofilters. The response of four biofilters operating in downfiow mode and reverse-flow mode was compared in a laboratory-scale plant treating CS_2 under sudden short-term changes in operating conditions. A process shutdown for 24 h, an inlet concentration increase and an interruption of the inlet air humidification for 48 h at an empty bed residence time (EBRT) of 240 s did not impact significantly on biodegradation performance, regardless of flow mode. Nevertheless, a reduction in the EBRT to 60 s resulted in a significant decrease in removal efficiency in all the biofilters. The CS_2 degradation profile showed that the reverse-flow mode strategy rendered a more homogenous distribution of biomass along the bed height. The benefits of the reverse-flow mode were demonstrated even when the unidirectional flow mode was re-established.
机译:二硫化碳(CS_2)的抑菌特性阻碍了其在常规生物滤池中的生物降解。在实验室规模的处理CS_2的工厂中,在突然的短期工作条件变化下,比较了四个以向下流模式和逆流模式运行的生物滤池的响应。不管流动方式如何,在240 s的空床停留时间(EBRT)下关闭过程24小时,入口浓度增加以及入口空气加湿中断48小时都不会对生物降解性能产生重大影响。然而,将EBRT降低至60 s会导致所有生物滤池的去除效率显着降低。 CS_2降解曲线表明,逆流模式策略使生物量沿床层高度分布更加均匀。即使重新建立了单向流动模式,也证明了反向流动模式的好处。

著录项

  • 来源
    《Bioprocess and Biosystems Engineering》 |2013年第4期|389-397|共9页
  • 作者单位

    Department of Chemical and Environmental Engineering,Engineering Faculty, University of the Basque Country (UPV/EHU), Alda Urkijo s, 48013 Bilbao, Spain;

    Department of Chemical and Environmental Engineering,Engineering Faculty, University of the Basque Country (UPV/EHU), Alda Urkijo s, 48013 Bilbao, Spain;

    Department of Chemical and Environmental Engineering,Engineering Faculty, University of the Basque Country (UPV/EHU), Alda Urkijo s, 48013 Bilbao, Spain;

    Department of Chemical and Environmental Engineering,Engineering Faculty, University of the Basque Country (UPV/EHU), Alda Urkijo s, 48013 Bilbao, Spain;

    Department of Chemical and Environmental Engineering,Engineering Faculty, University of the Basque Country (UPV/EHU), Alda Urkijo s, 48013 Bilbao, Spain;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    carbon disulphide; reverse-flow mode; empty bed residence time; conventional biofilters;

    机译:二硫化碳逆流模式;空床停留时间;常规生物滤池;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号