Thermal and moisture monitoring of an internally insulated historic brick wall

机译:内部隔热历史悠久的砖墙的温度和湿度监测

获取原文
获取原文并翻译 | 示例
           

摘要

Internally insulating walls is an effective method of energy retrofitting buildings. However insulation changes the hygric behaviour of a wall and can increase the risk of wall decay by moisture accumulation. This paper investigates thermal and moisture behaviour of internal insulations applied to a brick wall over a two and a half year period with probes positioned near the interface between the leveling plaster and brick wall.