...
首页> 外文期刊>Anais da Academia Brasileira de Ciencias >Comparative studies of two dimensional and three dimensional ultrasonic nuchal translucency in trisomy assessments
【24h】

Comparative studies of two dimensional and three dimensional ultrasonic nuchal translucency in trisomy assessments

机译:二维和三维超声颈部半透明性三体性评估的比较研究

获取原文
           

摘要

Current two-dimensional (2D) ultrasonic marker measurements are inherent with intra- and inter-observer variability limitations. The objective of this paper is to investigate the performance of conventional 2D ultrasonic marker measurements and proposed programmable interactive three-dimensional (3D) marker evaluation. This is essentially important to analyze that the measurement on 3D volumetric measurement possesses higher impact and reproducibility vis-à-vis 2D measurement. Twenty three cases of prenatal ultrasound examination were obtained from collaborating hospital after Ethical Committee's approval. The measured 2D ultrasonic marker is Nuchal Translucency or commonly abbreviated as NT. Descriptive analysis of both 2D and 3D ultrasound measurement were calculated. Three trial measurements were taken for each method. Both data were tested with One-Sample Kolmogorov-Smirnov Test and results indicate that markers measurements were distributed normally with significant parametric values at 0.621 and 0.596 respectively. Computed mean and standard deviation for both measurement methods are 1.4495 ± 0.46490 (2D) and 1.3561 ± 0.50994 (3D). ANOVA test shows that computerized 3D measurements were found to be insignificantly different from the mean of conventional 2D at the significance level of 0.05. With Pearson's correlation coefficient value or R = 0.861, the result proves strong positive linear correlation between 2D and 3D ultrasonic measurements. Reproducibility and accuracy of 3D ultrasound in NT measurement was significantly increased compared with 2D B-mode ultrasound prenatal assessment. 3D reconstructed imaging has higher clinical values compare to 2D ultrasound images with less diagnostics information.
机译:当前的二维(2D)超声标记仪测量固有于观察者内部和观察者之间的可变性限制。本文的目的是研究常规2D超声标记物测量的性能以及建议的可编程交互式三维(3D)标记物评估。这对于分析3D体积测量相对于2D测量具有更高的影响力和重现性至关重要。经伦理委员会批准,从合作医院获得了23例产前超声检查。测得的2D超声标记是Nuchal Translucency或通常缩写为NT。计算了2D和3D超声测量的描述性分析。每种方法进行了三个试验测量。两项数据均通过一次样本Kolmogorov-Smirnov检验进行了测试,结果表明标记物的测量值呈正态分布,参数值分别为0.621和0.596。两种测量方法的计算平均值和标准偏差分别为1.4495±0.46490(2D)和1.3561±0.50994(3D)。方差分析测试显示,在显着性水平为0.05时,发现计算机化3D测量值与常规2D平均值无明显差异。使用Pearson相关系数值或R = 0.861,结果证明了2D和3D超声测量之间的强正线性相关性。与2D B型超声产前评估相比,NT测量中3D超声的重现性和准确性显着提高。 3D重建成像与2D超声图像相比具有更高的临床价值,而诊断信息却更少。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号