摘要

Static Var Compensator (SVC) is a popular FACTS device for providing reactive power support in power systems and its placement representing the location and size has significant influence on network loss, while keeping the voltage magnitudes within the acceptable range. This paper presents a Firefly algorithm based optimization strategy for placement of SVC in power systems with a view of minimizing the transmission loss besides keeping the voltage magnitude within the acceptable range. The method uses a self-adaptive scheme for tuning the parameters in the Firefly algorithm. The strategy is tested on three IEEE test systems and their results are presented to demonstrate its effectiveness.
机译:静态无功补偿器(SVC)是一种流行的FACTS设备,用于在电力系统中提供无功功率支持,其位置表示位置和大小对网络损耗有重大影响,同时将电压幅度保持在可接受的范围内。本文提出了一种基于Firefly算法的优化策略,用于将SVC放置在电力系统中,以最大程度地降低传输损耗,同时将电压幅度保持在可接受的范围内。该方法使用自适应方案来调整Firefly算法中的参数。该策略在三个IEEE测试系统上进行了测试,并给出了其结果以证明其有效性。