Objectives:This paper addresses a comparison between physical dosimetry and mathematical dose calculation in nuclear medicine.Materials and Methods:Dose rate was calculated by mathematical external dose calculation formula and by physical dosimetry from the surface of 38 adult patients’ body referred to nuclear medicine department. Results of the methods were compared and correlation and regression tests were also performed.Results:Although the physical dosimetry data in this study are in good consistency with other researches, they are much lower than the results of mathematical dose calculation formula. The correlation coefficient between measured dose rate with calculated values derived by mathematical formula was found to be 0.852 (P value=0.148).Conclusion:It seems that physical dosimetry data are more accurate than the results of mathematical dose calculation. In case of using mathematical dose calculation formula, other correction factors should be considered and applied for getting reliable data.
机译:目的:本文比较了核医学中物理剂量学与数学剂量计算之间的比较。材料与方法:通过数学外部剂量计算公式和物理剂量学,从转诊给核医学科的38名成年患者身体表面计算出剂量率。结果:尽管本研究的物理剂量学数据与其他研究具有很好的一致性,但远低于数学剂量计算公式的结果。测得的剂量率与通过数学公式得出的计算值之间的相关系数为0.852(P值= 0.148)。结论:似乎物理剂量学数据比数学剂量计算的结果更准确。如果使用数学剂量计算公式,则应考虑其他校正因子,并将其应用于获得可靠的数据。