This paper describes a novel measurement method to accurately measure the rotating shaft tilt angle of rotating machine for alignment or compensation using a dual-axis inclinometer. A model of the rotating shaft tilt angle measurement is established using a dual-axis inclinometer based on the designed mechanical structure, and the calculation equation between the rotating shaft tilt angle and the inclinometer axes outputs is derived under the condition that the inclinometer axes are perpendicular to the rotating shaft. The reversal measurement method is applied to decrease the effect of inclinometer drifts caused by temperature, to eliminate inclinometer and rotating shaft mechanical error and inclinometer systematic error to attain high measurement accuracy. The uncertainty estimation shows that the accuracy of rotating shaft tilt angle measurement depends mainly on the inclinometer uncertainty and its uncertainty is almost the same as the inclinometer uncertainty in the simulation. The experimental results indicate that measurement time is 4 seconds; the range of rotating shaft tilt angle is 0.002° and its standard deviation is 0.0006° using NS-5/P2 inclinometer, whose precision and resolution are ±0.01° and 0.0005°, respectively.
机译:本文介绍了一种新颖的测量方法,该方法可使用双轴测斜仪精确测量旋转机器的旋转轴倾斜角以进行对准或补偿。根据设计的机械结构,采用双轴倾角仪建立了转轴倾角测量模型,推导了在倾角仪轴垂直的情况下转轴倾角与倾角仪轴输出之间的计算公式。到旋转轴上。采用反向测量方法,可以减小温度引起的测斜仪漂移的影响,消除测斜仪和转轴的机械误差和测斜仪系统误差,达到较高的测量精度。不确定度估计表明,旋转轴倾斜角测量的精度主要取决于倾角仪的不确定度,其不确定度与仿真中的倾角仪的不确定度几乎相同。实验结果表明,测量时间为4秒。使用NS-5 / P2倾角仪,旋转轴倾斜角的范围为0.002°,其标准偏差为0.0006°,其精度和分辨率分别为±0.01°和0.0005°。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号