The multi-sphere method, a neutron detection technique, has been improved with a BF3 long cylindrical counter as a thermal detector located in the center of seven spheres with a diameter range of 3.5 to 12 inches. Energy response functions of the system have been determined by applying the MCNP4C Monte Carlo code of 10-8 MeV to 18 MeV. A new shadow cone has been designed to account for scattered neutrons. Although the newly designed shadow cone is smaller in length, its attenuation coefficient has been improved. To evaluate the system, the neutron spectrum of a 241AM-Be source has been measured.
机译:多球方法(一种中子检测技术)已通过将BF3长圆柱计数器作为热探测器进行了改进,该计数器位于直径范围为3.5到12英寸的七个球的中心。系统的能量响应功能已通过将10-8 MeV的MCNP4C蒙特卡洛代码应用于18 MeV来确定。设计了一个新的阴影锥,以解释散射中子。尽管新设计的阴影锥长度较小,但其衰减系数得到了改善。为了评估该系统,已经测量了241AM-Be源的中子光谱。