首页> 外文期刊>Journal of Optometry >Intraocular straylight screening in medical testing centres for driver licence holders in Spain
【24h】

Intraocular straylight screening in medical testing centres for driver licence holders in Spain

机译:在西班牙为驾驶员执照持有人在医疗测试中心进行眼内杂散光检查

获取原文
       

摘要

Purpose: To test the performance of the C-quant straylight meter during the daily routine work in medical testing centres for driver license applicants and driver license holders in Spain. Methods: Altogether 914 subjects, of which 376 younger than 35 years, 428 between 35 and 60 years and 110 over 60 years were measured with the C-quant in three medical testing centres (Barcelona, Zaragoza and Palma de Mallorca) in 2006. Technicians were instructed once and the measurements were done during the daily routine work. We recorded: age, BCVA, self-reported subjective blinding at night; and from the C-quant: straylight parameter (log s), measurement quality parameters (ESD, Q) and test duration. Results: Total C-quant test duration increases slightly with age from a mean of 7 min ( 60). At first attempt, 82 % of all subjects produced reliable results (ESD < 0.12). The straylight parameter for this group was independent of ESD and ESD was independent of total test duration. The known age dependence of the straylight parameter and the weak correlation with BCVA was confirmed. The distribution of subjective blinding at night was very different between test centres. Subjects with ''very strong'' subjective blinding had significantly higher straylight values than subjects with ''no'' subjective blinding. Subjects avoiding night driving had significant higher straylight values than subjects driving at night. Conclusion: The C-quant measure is reasonable fast. Good subject instruction is important to get first attempt reliable results. Self-reported subjective blinding results depend strongly on the interviewer.
机译:目的:在西班牙的驾驶执照申请人和驾驶执照持有人的医疗检测中心日常工作中,测试C量杂散光计的性能。方法:2006年,在三个医学检验中心(巴塞罗那,萨拉戈萨和马洛卡帕尔玛)使用C量表对914位受试者进行了测量,其中376位年龄小于35岁的年轻人,428位年龄在35至60岁之间的男孩和60岁以上的110位。接受一次指导,并在日常工作中进行测量。我们记录了:年龄,BCVA,夜间自我报告的主观失明;并从C量级:杂散光参数(log s),测量质量参数(ESD,Q)和测试持续时间。结果:总C量测试持续时间随着年龄的增长而略有增加,平均为7分钟(60)。首次尝试时,所有受试者中有82%产生了可靠的结果(ESD <0.12)。该组的杂散光参数与ESD无关,而ESD与总测试时间无关。证实了杂散参数的已知年龄依赖性以及与BCVA的弱相关性。考试中心之间晚上的主观盲区分布非常不同。主观盲为“非常强”的受试者比主观盲为“无”的受试者具有更高的杂散光值。避免夜间驾驶的受试者的杂散光值明显高于夜间驾驶的受试者。结论:C-quant量度是合理的快速。良好的学科指导对于获得首次尝试的可靠结果很重要。自我报告的主观致盲结果在很大程度上取决于访问员。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号