Introduction: Oxygen saturation is considered as the 5th vital sign. Presently, there exist fixed and wireless pulse oximeters, being the latter most widely used in the last years. Some of them have no possibility of calibration. This situation leads the health staff to adopt therapeutic attitudes which can be wrong. Therefore, it is extremely important to know if these wireless oximeters show a right concordance as regards measurements, since it is of great interest in daily clinical practice.Objective: To evaluate concordance among measurements obtained by three different pulse oximeters currently used by health professionals.Materials and Methods: This is an observational, descriptive and cross-sectional study related to the concordance of the results obtained in measurements collected by three different pulse oximeters (one monitor and two wireless oximeters) which are available and in use in this hospital unit. The sample size calculation was performed for a concordance above 0.81 and an estimation error which did not exceed 0.20. The intraclass correlation index (ICI) was used to establish the concordance whereas the Landis-Koch criteria were used to interpret the results. Systematic errors were analyzed using the Bland-Altman plot.Results: The overall concordance among the three pulse oximeters analyzed resulted in 0.88, a value considered as ?good? according to the Landis-Koch criteria.Conclusion: The results obtained show that in daily clinical practice both wireless pulse oximeters analyzed can be used with a certain reliability, taking into account the limitations of this research.
机译:简介:氧饱和度被认为是第五生命体征。当前,存在固定和无线脉搏血氧仪,后者是最近几年中使用最广泛的脉搏血氧仪。其中一些无法校准。这种情况导致卫生人员采取治疗态度,这可能是错误的。因此,了解这些无线血氧仪在测量方面是否显示正确的一致性非常重要,因为它在日常临床实践中引起了极大的兴趣。目的:评估当前由卫生专业人员使用的三种不同脉搏血氧仪获得的测量结果之间的一致性。材料和方法:这是一项观察性,描述性和横断面研究,与该医院单位使用的三种不同脉搏血氧仪(一台监护仪和两台无线血氧仪)收集的测量结果的一致性有关。进行大于0.81的一致性和不超过0.20的估计误差的样本量计算。组内相关指数(ICI)用于建立一致性,而Landis-Koch标准用于解释结果。结果:用分析的三个脉搏血氧仪的总体一致性为0.88,该值被认为是“良好”。结论:得出的结果表明,在日常临床实践中,考虑到本研究的局限性,所分析的两种无线脉搏血氧仪均可可靠地使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号