摘要

Large defect-free domains of a hexagonal packed monolayer of silica spheres with the size of 4000 μm2 were successfully prepared by dual-speed spin coating. Experimental design and statistical analysis instead of the traditional ‘changing one separate factor at a time’ (COST) approach were employed to guide the implementation of the experiments. With its assistance, the hexagonal-close-packed (HCP) percentage was elevated to 84% in this study. Furthermore, almost all the samples with parameters in the selected ranges possessed more than a 60% HCP percentage. In addition, the optimal values for parameters of the suspension concentration, the first rotation speed, and the spinning time to obtain well-ordered silica spheres arrays were also identified as 30 wt.%, 1000 rpm and 20 s, respectively.
机译:通过双速旋涂成功制备尺寸为4000μm2的六角形填充单层的大型缺陷域。 实验设计和统计分析,而不是传统的“时代改变一个单独的因素”(成本)方法是用于指导实验的实施。 凭借其辅助,六边形 - 紧密包装(HCP)百分比升高至本研究的84%。 此外,所选范围中具有参数的几乎所有样本都具有超过60%的HCP百分比。 另外,悬浮浓度的参数,第一转速和纺丝时间以获得井有序的二氧化硅球阵列的最佳值也被鉴定为30重量%,1000rpm和20s。