首页> 外文期刊>Electric power systems research >Characterization of the effect of the insulating material of covered cables on the impulse breakdown behavior of single- and three-phase compact distribution lines
【24h】

Characterization of the effect of the insulating material of covered cables on the impulse breakdown behavior of single- and three-phase compact distribution lines

机译:包覆电缆绝缘材料对单相和三相紧凑型配电线路的脉冲击穿行为的影响

获取原文
获取原文并翻译 | 示例
           

摘要

This paper aims to characterize the influence of the insulating material of covered cables on the impulse breakdown behavior of typical single- and three-phase compact distribution line configurations. Based on high voltage tests with standard lightning impulse voltages, three main features are investigated: (i) minimal values of breakdown voltage, (ii) time for disruption, and (iii) pinhole location. The results indicate larger withstand levels for the single- and three-phase structures when high-density polyethylene (HDPE) is used instead of crosslinked polyethylene (XLPE) in the insulating layer of the cables. Differences up to 60% are reported. Also, HDPE-covered cable presents a shorter time for disruption. Typically, voltage breakdown was observed in the wavefront for HDPE-covered cables and in the wavetail for XLPE-covered cables. Finally, tests with punctured samples showed that the value of the disruptive voltage is influenced by the pinhole location along the cable cover.
机译:本文旨在表征被覆电缆的绝缘材料对典型的单相和三相紧凑型配电线路配置的脉冲击穿行为的影响。基于具有标准雷电冲击电压的高压测试,研究了三个主要特征:(i)击穿电压的最小值,(ii)破坏时间和(iii)针孔位置。结果表明,当在电缆的绝缘层中使用高密度聚乙烯(HDPE)代替交联聚乙烯(XLPE)时,单相和三相结构的承受力更大。据报道差异高达60%。而且,HDPE覆盖的电缆可以缩短中断时间。通常,对于HDPE覆盖的电缆,在波前和XLPE覆盖的电缆的波前都观察到电压击穿。最后,对穿刺样品的测试表明,破坏性电压的值受沿电缆盖针孔位置的影响。

著录项

  • 来源
    《Electric power systems research》 |2019年第7期|161-166|共6页
  • 作者单位

    Univ Fed Minas Gerais, Grad Program Elect Engn, LRC, 6627 Antonio Carlos Ave, BR-31270901 Belo Horizonte, MG, Brazil|UniBH Univ Ctr Belo Horizonte, 1685 Prof Mario Werneck Ave, BR-30455610 Belo Horizonte, MG, Brazil;

    Univ Fed Minas Gerais, Grad Program Elect Engn, LRC, 6627 Antonio Carlos Ave, BR-31270901 Belo Horizonte, MG, Brazil;

    Univ Fed Minas Gerais, Grad Program Elect Engn, LRC, 6627 Antonio Carlos Ave, BR-31270901 Belo Horizonte, MG, Brazil;

    Univ Fed Minas Gerais, Grad Program Elect Engn, LRC, 6627 Antonio Carlos Ave, BR-31270901 Belo Horizonte, MG, Brazil|IFMG Fed Inst Minas Gerais, 2590 Prof Mario Werneck Ave, BR-30575180 Belo Horizonte, MG, Brazil;

    Univ Fed Minas Gerais, Grad Program Elect Engn, LRC, 6627 Antonio Carlos Ave, BR-31270901 Belo Horizonte, MG, Brazil;

    Univ Fed Minas Gerais, Grad Program Elect Engn, LRC, 6627 Antonio Carlos Ave, BR-31270901 Belo Horizonte, MG, Brazil;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Breakdown; Compact distribution lines; Impulse voltage; Withstand; Pinhole formation; XLPE- and HDPE-covered cables;

    机译:击穿;紧凑的配电线路;冲击电压;耐压;针孔形成;XLPE和HDPE覆盖的电缆;