首页> 外文期刊>Electric power systems research >Comparison of steady state characteristics of shunt, short-shunt and long-shunt induction generators
【24h】

Comparison of steady state characteristics of shunt, short-shunt and long-shunt induction generators

机译:并联,短并联和长并联感应发电机的稳态特性比较

获取原文
获取原文并翻译 | 示例
           

摘要

This paper presents a comparative study of steady state characteristics of a self-excited induction generator operating in shunt, short-shunt and long-shunt configurations. First the steady state problem of the generator, for all three operating configurations, is formulated in a very general way and represented by a single set of equations. A numerical based routine is then employed to solve the formulated problem without explicitly expressing the equations in terms of actual unknowns. The effectiveness of the proposed method is then vigorously tested on a three-phase, 1.5-kW induction generator operating in shunt, short-shunt and long-shunt configurations. The simulation results obtained by the proposed method are also compared with the corresponding actual values found through an experimental setup and are observed to be in very good agreement.
机译:本文对以并联,短并联和长并联配置运行的自激感应发电机的稳态特性进行了比较研究。首先,对于发电机的所有三种运行配置,其稳态问题都以一种非常通用的方式来表述,并由一组方程式表示。然后采用基于数字的例程来解决公式化的问题,而无需根据实际未知数明确表示方程式。然后在分流,短分流和长分流配置下的三相1.5 kW三相感应发电机上对所提出方法的有效性进行了严格测试。通过提议的方法获得的仿真结果也与通过实验设置找到的相应实际值进行比较,并且观察到非常一致。