摘要

This paper reports observations of partial discharges (PD) occurring within the stators of random wound electric motors during surge comparison testing, and discusses criteria for limiting testing levels to avoid initiation of insulation defects. Random wound electric motors are constructed by forming coils from a number of turns of insulated wire and placing these into the stator. One common form of motor failure involves electrical breakdown between turns, which subsequently develops into a breakdown to earth or between phases. Motor manufacturers and rewinders commonly use a surge comparison tester to determine whether a new winding is free from winding defects such as shorted turns or damaged turn insulation. Partial discharges are an indication of insulation weakness and can also damage the insulation without being detected during surge comparison testing.
机译:本文报告了在浪涌比较测试期间随机缠绕的电动机的定子中发生的局部放电(PD)的观察结果,并讨论了限制测试级别以避免引发绝缘缺陷的标准。随机绕线电动机是由多匝绝缘电线形成线圈并将其放入定子中构成的。电动机故障的一种常见形式涉及匝之间的电击穿,其随后发展为对地或两相之间的击穿。电机制造商和重绕机通常使用电涌比较测试仪来确定新绕组是否没有绕组缺陷,例如匝数短路或绕组绝缘损坏。局部放电是绝缘薄弱的一个指示,也可能在电涌比较测试期间未检测到绝缘而损坏绝缘。