首页> 外文期刊>Fuel >The densities of three biodiesel fuels at temperatures up to 300 deg C
【24h】

The densities of three biodiesel fuels at temperatures up to 300 deg C

机译:三种生物柴油燃料在高达300摄氏度的温度下的密度

获取原文
获取原文并翻译 | 示例
           

摘要

In order to obtain the densities of biodiesel fuels at temperatures up to 300 deg C, a capacitance type liquid level meter was designed to measure the increase in volume of 50 ml of three commercial biodiesel fuels over the temperature range of 20-300 deg C. Densities were measured for methyl esters of canola and soy and ethyl esters offish-oil. The frequency output from the meter was linear with temperature and liquid level. Frequencies were recorded in kHz to within three decimal places and had sensitivities of 0.040 kHz/ deg C and - 2.740 kHz/cm for temperature and submergence depth, respectively. Derived densities were found to be linear with temperature over the measured range. Used in this fashion, the level meter can be considered a precise densitometer with a repeatability of 1 percent.
机译:为了获得在高达300摄氏度的温度下生物柴油燃料的密度,设计了一种电容式液位计,以测量在20-300摄氏度的温度范围内三种工业生物柴油燃料在50毫升中体积的增加。测量低芥酸菜子和大豆的甲酯和鱼油的乙酯的密度。仪表输出的频率与温度和液位成线性关系。频率以kHz记录到小数点后三位以内,其温度和浸入深度的灵敏度分别为0.040 kHz /℃和-2.740 kHz / cm。发现在测量范围内,得出的密度与温度呈线性关系。以这种方式使用的液位计可以被认为是一种精密的密度计,其重复性为1%。