CIRUS is a 40 MWth, light water cooled research reactor located at Trombay, Mumbai. The reactor was shut down in 1997 for refurbishment and restarted in 2003. At Bhabha Atomic Research Centre R&D activities on desalination have led to development of desalination technologies based on Multistage Flash (MSF) evaporation, Reverse Osmosis (RO) and Low Temperature Evaporation (LTE). Based on LTE, a 30 cubic metre per day pilot plant was designed and integrated to CIRUS during refurbishing outage as part of demonstration of utilisation of waste heat of nuclear reactors for seawater desalination. The work involved design, installation and commissioning of set-up to transfer heat from primary coolant of CIRUS to desalination unit through an intermediate Demineralised (DM) water circuit. The unit has been operated at its rated capacity and product water has been used to augment the demineralised water inventory of the primary coolant system. This paper highlights the experience gained during installation, commissioning and operation of the desalination unit.
机译:CIRUS是位于孟买Trombay的40兆瓦时轻水冷却研究堆。该反应堆于1997年关闭以进行翻新,并于2003年重新启动。在Bhabha原子研究中心,有关脱盐的研发活动已导致开发基于多级闪蒸(MSF)蒸发,反渗透(RO)和低温蒸发(LTE)的脱盐技术。 )。基于LTE,设计了每天30立方米的中试装置,并在翻修中断期间将其集成到CIRUS中,以演示利用核反应堆的废热进行海水淡化。这项工作涉及设备的设计,安装和调试,以通过中间的脱矿质(DM)水回路将热量从CIRUS的主要冷却剂传递到脱盐装置。该设备已按其额定容量运行,产品水已用于增加主冷却剂系统的软化水库存。本文重点介绍了在脱盐装置的安装,调试和操作过程中获得的经验。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号