Dc breakdown studies on Mylar film show that defects cause a decrease in dielectric strength with decreasing film thickness at room temperature but not at -180°C. The breakdown at defects is associated with moisture content. Using self‐healing electrodes to eliminate weak areas, a dc dielectric strength of 6 Mv/cm is found, independent of film thickness. Prebreakdown current measurements indicate ionic currents which are fairly uniform throughout a sample, and field emission currents localized at incipient breakdown points. Breakdown probably occurs as a result of local heating by field emission currents.
机译:对聚酯薄膜的Dc击穿研究表明,缺陷会导致介电强度降低,在室温下会降低薄膜厚度,但在-180°C下不会降低。缺陷处的击穿与水分含量有关。使用自愈电极消除薄弱区域,发现直流绝缘强度为6 Mv / cm,与膜厚无关。击穿前的电流测量表明整个样品中离子电流相当均匀,场发射电流位于初始击穿点。击穿可能是由于场发射电流引起的局部加热而发生的。