An Experimental Modeling and Investigation of Change in Cold Mass Fraction and Nozzle Numbers on Performance of Counter Flow Vortex Tube

机译:冷质量分数和喷嘴数量变化对逆流涡流管性能的实验建模和研究

获取原文
获取原文并翻译 | 示例
           

摘要

An experimental investigation has been performed to realize thorough behavior of a vortex tube system. The vortex tube is a simple device operating as a refrigerating unit without any moving parts. It consists of a principal tube, to which a high pressure gas stream enters tangentially where it splits into two streams: one hot and one cold temperature streams. This paper discusses the experimental investigation of vortex tube performance as it relates to cold mass fraction, and nozzle number. Four different orifices, each with three, four, five and six nozzles respectively, were manufactured and used during the test. The experiments have been conducted with each one of those orifices stated above, and the performance of the vortex tube has been tested with air at inlet pressure of 5 bar and the cold mass fractions of 0.5-0.72.
机译:为了实现涡流管系统的彻底性能,已经进行了实验研究。涡流管是一种简单的装置,可作为制冷装置运行,没有任何活动部件。它由一个主管组成,高压气流切向进入其中,并分成两股流:一股热和一股冷气流。本文讨论了涡流管性能的实验研究,它与冷质量分数和喷嘴数量有关。在测试过程中,制造并使用了四个不同的孔,每个孔分别具有三个,四个,五个和六个喷嘴。已经对上述每个孔进行了实验,并且在进气压力为5 bar,冷质量分数为0.5-0.72的空气中测试了涡流管的性能。