A rapid distillation method coupled with ion chromatography was developed for simultaneous determination of methylamine, ethylamine, dimethylamine, trimethylamine, propylamine, and butylamine in cosmetics. The distillation system was designed professionally to achieve rapid distillation in less than 3Â min and eliminate the interferences of alkali metals, alkaline earth, and organic compounds effectively. Samples were distilled using vapor stream under alkaline conditions and the distilled products were absorbed in acetic acid solution prior to detection. The linear ranges of alkylamines were within 0.1-18Â mg/L and the detection limits ranged from 0.045Â mg/L to 0.075Â mg/L. The method was successfully utilized to determine the amount of alkylamines in commercial cosmetics without need for tedious pretreatments. Average recoveries ranged from 84.4% to 108.5% with relative standard deviations (RSD) in the range of 0.7-7.6%. Validation results indicated that the method was simple, accurate, precise, selective, and suitable for the determination of alkylamines in cosmetics.View full textDownload full textKeywordsalkylamine, cosmetics, ion chromatography (IC), rapid distillation, sample pretreatment, suppressed conductivity detection healthRelated var addthis_config = { ui_cobrand: "Taylor & Francis Online", services_compact: "citeulike,netvibes,twitter,technorati,delicious,linkedin,facebook,stumbleupon,digg,google,more", pubid: "ra-4dff56cd6bb1830b" }; Add to shortlist Link Permalink http://dx.doi.org/10.1080/10826076.2011.621773
机译:建立了快速蒸馏与离子色谱联用的方法,用于同时测定化妆品中的甲胺,乙胺,二甲胺,三甲胺,丙胺和丁胺。蒸馏系统是专业设计的,可在不到3分钟的时间内实现快速蒸馏,并有效消除碱金属,碱土和有机化合物的干扰。在碱性条件下使用蒸气流对样品进行蒸馏,并在检测之前将蒸馏的产物吸收在乙酸溶液中。烷基胺的线性范围是在0.1-18 mg / L之内,并且检测极限范围是0.045 mg / L至0.075 mg / L。该方法已成功用于测定商业化妆品中烷基胺的量,而无需进行繁琐的预处理。平均回收率在84.4%至108.5%之间,相对标准偏差(RSD)在0.7-7.6%的范围内。验证结果表明,该方法简便,准确,准确,选择性强,适用于化妆品中烷基胺的测定。查看全文下载全文关键词烷基胺,化妆品,离子色谱法(IC),快速蒸馏,样品预处理,抑制电导率检测健康相关变量addthis_config = {ui_cobrand:“泰勒和弗朗西斯在线”,servicescompact:“ citeulike,netvibes,twitter,technorati,delicious,linkedin,facebook,stumbleupon,digg,google,更多”,发布:“ ra-4dff56cd6bb1830b”};添加到候选列表链接永久链接http://dx.doi.org/10.1080/10826076.2011.621773

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号