We conducted and verified the structural safety analyses for a type B transport package for a radioactive waste drum. The type B package is used to transport one high-level radioactive waste drum from a waste facility to a temporary site in a nuclear power plant. It is important that the structural integrity of a type B transport package should be maintained under normal transport conditions such as the free drop test, the stacking test and the penetration test, and accident conditions of transport such as the 9 m height free drop test and the puncture test. Based on the ASME Boiler and Pressure Vessel Code, Section III, Division 3 we evaluated the structural safety integrity of the type B package for a radioactive waste drum using finite element analysis. For the stacking test condition the maximum stress is a very low value when compared with the stress limits. The impact of the penetration bar on the overpack does not affect the containment part. For the free drop test condition and the puncture test condition the local stresses appear at the impact part and the containment part connected with the inner structure. The maximum stresses for all of the conditions are lower than the stress limits, so the structural integrity of the type B package for a radioactive waste drum was maintained. Also, the structural safety analyses were verified by using the data acquired from the 9 m drop and the puncture tests of the real model. The analytic accelerations of the 9 m drop test are similar to the test results. For the puncture test condition the analytic result is conservative when compared to the test. The analysis for the structural safety of the type B package reveals conservative results and it is proved that its structural integrity is maintained under normal and accident conditions of transport.
机译:我们对放射性废物桶的B型运输包装进行并验证了结构安全性分析。 B型包装用于将一个高放射性废物桶从废物设施运输到核电站的临时站点。重要的是,B型运输包装的结构完整性应在正常运输条件下保持,例如自由下落试验,堆叠试验和穿透试验,以及在意外事故条件下(例如9 m高自由下落试验和穿刺测试。根据ASME锅炉和压力容器规范第III节第3部分,我们使用有限元分析评估了放射性废料桶的B型包装的结构安全完整性。对于堆叠测试条件,与应力极限相比,最大应力是一个非常低的值。渗透条对外包装的影响不会影响包装部件。对于自由落体试验条件和穿刺试验条件,局部应力出现在与内部结构连接的冲击部分和容纳部分上。在所有条件下的最大应力都低于应力极限,因此,用于放射性废物鼓的B型包装的结构完整性得以保持。此外,通过使用从9 m跌落获取的数据和真实模型的穿刺测试,对结构安全性分析进行了验证。 9 m跌落测试的解析加速度类似于测试结果。对于穿刺测试条件,与测试相比,分析结果较为保守。 B型包装的结构安全性分析显示出保守的结果,并证明了在正常运输和事故运输条件下都能保持其结构完整性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号