首页> 外文期刊>Optical and quantum electronics >Clinical experience with Bausch & Lomb Technolas-217 excimer laser
【24h】

Clinical experience with Bausch & Lomb Technolas-217 excimer laser

机译:Bausch&Lomb Technolas-217准分子激光的临床经验

获取原文
获取原文并翻译 | 示例
           

摘要

We retrospectively followed up 177 eyes of 90 myopic patients who had received laser in situ keratomileusis (LASIK) using Bausch & Lomb Technolas-217 laser. All patients underwent comprehensive preoperative ophthalmologic examinations. Results were analyzed from examinations performed at 1 week, 1, 3 and 6 months intervals after surgery. The preoperative mean spherical equivalent refraction was -6.19 D. The 6-month follow-up rate was 86%. The mean postoperative spherical equivalent refraction was -0.28 D. Thirty-two percent of eyes achieved 1.5 or better uncorrected visual acuity (UCVA), 86% of eyes achieved 1.2 or better UCVA and 98% achieved 1.0 or better UCVA. The safety, efficacy, predictability and the visual results were proved to be excellent.
机译:我们回顾性随访了使用博士伦(Lausch&Lomb Technolas-217)激光接受原位角膜磨镶术(LASIK)的90名近视患者的177眼。所有患者均接受了术前全面的眼科检查。从手术后1周,1、3和6个月的间隔中进行的检查分析结果。术前平均等效球镜屈光度为-6.19D。6个月的随访率为86%。术后平均等效球镜屈光度为-0.28D。32%的眼睛获得1.5或更高的未矫正视力(UCVA),86%的眼睛获得UCVA达到1.2或更高,98%的眼睛获得1.0或更高的UCVA。安全性,有效性,可预测性和视觉效果均被证明是极好的。