This study presents a procedure for tuning proportional-integral/proportional-integral-derivative controllers using the frequency response method via Bode diagrams, which is relatively simple and easy to understand, and can be used when phase margin and 0 dB gain crossover frequency are project specifications. The method is validated in a practical power electronics application, considering the current and the DC-bus voltage loops of a shunt active power filter (SAPF). A detailed analysis related to the obtaining of the DC-bus voltage loop is also provided. In addition, a stability analysis is presented, considering how the SAPF compensation current is influenced according to the load current, taking into account different values of the grid impedance. Simulation and practical results show the effectiveness of the proposed scheme and its simplicity for being considered in practical cases.
机译:这项研究提出了一种通过Bode图使用频率响应方法对比例积分/比例积分微分控制器进行调谐的程序,该程序相对简单易懂,可用于计划相位裕度和0 dB增益交叉频率的情况。规格。考虑到并联有源功率滤波器(SAPF)的电流和DC总线电压环路,该方法已在实际的电力电子应用中得到验证。还提供了与获取直流母线电压环路有关的详细分析。此外,考虑到电网阻抗的不同值,考虑到SAPF补偿电流如何根据负载电流受到影响,提出了稳定性分析。仿真和实际结果表明了该方案的有效性及其在实际情况下的简便性。