Short-term measurements of kerma rate from external radiation in the environment have been performed simul- taneously at 100 locations over an area of about 15, 000 km~2 using the Rapid Assessment of Accidental Exposures (RACE) system which is based on LiF:Mg, Cu, P (MCP-N) ultra-sensitive thermoluminescent detectors. The short-term exposure lasted about 5 days, a total of about 128 h between pre-exposure annealing and readout, of which the exposure of the detector at the measurement site lasted about 96 h.
机译:使用基于LiF的事故暴露快速评估(RACE)系统,在大约15、000 km〜2的区域内的100个位置同时进行了环境中外部辐射的比释动能率的短期测量: Mg,Cu,P(MCP-N)超灵敏热发光探测器。短期暴露持续约5天,在暴露前退火和读出之间总共约128 h,其中检测器在测量部位的暴露持续约96 h。