首页> 外文期刊>Sensors Journal, IEEE >Parametric Amplification of Magnetic Resonance Images
【24h】

Parametric Amplification of Magnetic Resonance Images

机译:磁共振图像的参数放大

获取原文
获取原文并翻译 | 示例
           

摘要

Parametric amplification is considered as a method for the detection of magnetic resonance imaging (MRI) signals. The theory of three-frequency amplifiers is reviewed, and aspects relevant to radio-frequency detection are highlighted. The modifications needed for MRI are described, and a parametrically amplified surface coil for 63.85 MHz operation is demonstrated. Electrical characterization is carried out, and good agreement is obtained with the theory. A linear gain of 100 (40 dB power gain) and a Q-factor of 18 000 are demonstrated. 1H MRI is carried out at 1.5 T and frequency-domain filtering of images is demonstrated.
机译:参数放大被认为是用于检测磁共振成像(MRI)信号的方法。回顾了三频放大器的原理,并着重介绍了与射频检测有关的方面。描述了MRI所需的修改,并演示了用于63.85 MHz操作的参数放大的表面线圈。进行了电气表征,并与理论取得了良好的一致性。线性增益为100(功率增益为40 dB),Q因子为18 000。在1.5 T下进行 1 H MRI,并证明了图像的频域滤波。