An 8$,times,$ 16 pixel array based on CMOS small-area silicon photomultipliers (mini-SiPMs) detectors for PET applications is reported. Each pixel is 570 $,times,$610 $mu$m $^{{2}}$ in size and contains four digital mini-SiPMs, for a total of 720 SPADs, resulting in a full chip fill-factor of 35.7%. For each gamma detection, the pixel provides the total detected energy and a timestamp, obtained through two 7-b counters and two 12-b 64-ps TDCs. An adder tree overlaid on top of the pixel array sums the sensor total counts at up to 100 Msamples/s, which are then used for detecting the asynchronous gamma events on-chip, while also being output in real-time. Characterization of gamma detection performance with an 3 $,times,$3 $,times,$5 mm $^{{3}}$ LYSO scintillator at 20 $^{circ}$C is reported, showing a 511-keV gamma energy resolution of 10.9% and a coincidence timing resolution of 399 ps.
机译:报道了一种基于CMOS小面积硅光电倍增管(mini-SiPM)检测器的8×16像素阵列,用于PET应用。每个像素的大小为570美元×610美元/μm,并且包含四个数字微型SiPM,共720个SPAD,因此全芯片填充率为35.7%。对于每个伽马检测,像素提供通过两个7-b计数器和两个12-b 64-ps TDC获得的总检测能量和时间戳。覆盖在像素阵列顶部的加法器树以最高100 Msamples / s的速度对传感器总计数求和,然后将其用于检测片上异步伽马事件,同时也实时输出。据报道,在20°C ^ 3C的条件下,使用3×3×5mm的LYSO闪烁体对γ探测性能进行了表征,显示511keV的γ能量分辨率为10.9%的重合时间分辨率为399 ps。