Reliability of a novel procedure to monitor the flexibility of lower limb muscle groups in highly-trained adolescent athletes

机译:监测受过训练的青少年运动员下肢肌肉群灵活性的新方法的可靠性

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Objectives: To evaluate the reliability level of an innovative method using a standardized stretch force to assess the flexibility of lower limb muscle groups in highly-trained adolescent athletes and to examine whether interchanging the examiners affects the reliability of the measures. Design: Randomized test-retest study. Setting and participants: In ten athletes, the flexibility of eight lower limb muscle groups was examined on two occasions on both sides and in two phases: a video capture by three distinct operators and an analysis by three distinct analysers. The reliability of the measures was assessed by the coefficient of variation (CV, 90% CI). Between-analysers and between-operators standardized differences (i.e., Cohen's d) were calculated. Results: CV (%, 90% CI) were 8.3% (7.5; 9.3) for quadriceps, 3.3% (3.0; 3.7) for hamstrings, 7.2% (6.5-8.0) for adductors, 5.7% (5.1; 6.3) for gastrocnemius, 4.5% (4.0; 5.0) for soleus, 2.6% (2.3; 2.9) for hip flexors, 9.6% (8.6; 10.8) for hip medial rotators and 12.4% (12.2; 14.0) for hip lateral rotators. There was no substantial (i.e., Cohen's d < 0.2) difference in CV between all the possible operators/analysers combinations. Conclusion: This method has a moderate-to-good reliability level and is examiner-independent. It may be implemented in future injury prevention programs, in order to monitor the flexibility of highly-trained adolescent athletes. ? 2012 Elsevier Ltd.
机译:目的:评估使用标准化拉伸力的创新方法的可靠性水平,以评估训练有素的青少年运动员下肢肌肉群的柔韧性,并检查更换检查员是否会影响措施的可靠性。设计:随机重测研究。背景和参与者:在十名运动员中,在两侧和两个阶段分别两次检查了八个下肢肌肉群的柔韧性:三个截然不同的操作员进行视频捕获,并由三个截然不同的分析人员进行了分析。测量的可靠性通过变异系数(CV,90%CI)评估。分析人员之间和运营商之间的标准差(即Cohen d)被计算出来。结果:四头肌的CV(%,90%CI)为8.3%(7.5; 9.3),绳肌为3.3%(3.0; 3.7),内收肌为7.2%(6.5-8.0),腓肠肌为5.7%(5.1; 6.3) ,比目鱼肌占4.5%(4.0; 5.0),髋部屈肌占2.6%(2.3; 2.9),髋关节内侧旋转肌占9.6%(8.6; 10.8),髋关节外侧旋转肌占12.4%(12.2; 14.0)。所有可能的操作员/分析人员组合之间的CV差异不大(即Cohen d <0.2)。结论:该方法具有中等到良好的可靠性水平,并且与检查者无关。它可能会在未来的伤害预防计划中实施,以监控训练有素的青少年运动员的灵活性。 ? 2012爱思唯尔有限公司

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号