Ultrasonographic measurements of lower trapezius muscle thickness at rest and during isometric contraction: A reliability study

机译:静止和等距收缩过程中下斜方肌厚度的超声检查:可靠性研究

获取原文
获取原文并翻译 | 示例
           

摘要

Objective: The Purpose of this study was to determine the intra-rater reliability and inter-rater reliability of ultrasound imaging (USI) thickness measurements of the lower trapezius (LT) at rest and during active contractions when the transverse process and the lamina were used as reference sites for the measurement process. Participants: Twenty healthy individuals between the ages of 22 and 32 years volunteered. Methods: With the subject prone and the shoulder in 145° of abduction, images of the LT were taken bilaterally by one examiner as the subject: (1) rested; (2) actively held the test position; and (3) actively held the test position while holding a weight. Ten subjects returned and testing was repeated by the same examiner and by a second examiner. LT thickness measurements were recorded at the level of the transverse process and at the level of the lamina. Results: Intra-class correlation coefficients (ICC) for within session intra-rater reliability (ICC3,3) ranged from 0.951 to 0.986 for both measurement sites while between session intra-rater reliability (ICC3,2) ranged from 0.935 to 0.962. Within session inter-rater reliability (ICC2,2) ranged from 0.934 to 0.973. Conclusions: USI can be used to reliably measure LT thickness at rest, during active contraction and during active contraction when holding a weight. The described protocol can be utilized during shoulder examinations to provide an additional assessment tool for monitoring changes in LT thickness.
机译:目的:本研究的目的是确定静止和活动收缩时使用横向过程和椎板时下斜方肌(LT)的超声成像(USI)厚度测量的评定者内可靠性和评定者间可靠性作为测量过程的参考点。参与者:20名年龄在22至32岁之间的健康人自愿参加。方法:将受检者俯卧和肩部外展角度为145°,由一名检查者从两侧拍摄LT图像:(1)休息; (2)积极担任测试职务; (3)在保持重量的同时主动保持测试位置。返回了十名受试者,同一位检查员和第二位检查员重复了测试。 LT厚度测量值记录在横向过程的水平和薄片的水平。结果:两个测量地点的会话内评估者可靠性(ICC3,3)的类内相关系数(ICC)在0.951至0.986之间,而会话内评估者可靠性之间的类内相关系数(ICC3,2)在0.935至0.962之间。在会话中,评估者之间的可靠性(ICC2,2)为0.934至0.973。结论:USI可用于可靠地测量静止,活动收缩期间和保持体重时活动收缩期间的LT厚度。可以在肩部检查过程中使用所描述的协议,以提供额外的评估工具来监视LT厚度的变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号