Measurement error (ME) is caused by measuring instruments and the systems QS 9000 and ISOI TS 16949 have defined gauge capability acceptable criteria based on PIT value. However, instruments with accuracy degeneration are common in reliability engineering. This renders PIT value inadequate. In this setting, a modified index PIT* is proposed to judge gauge capability along with its estimator for the case where a part can be measured only once and only one instrument is used. (18 refs.)
机译:测量误差(ME)是由测量仪器引起的,并且系统QS 9000和ISOI TS 16949已基于PIT值定义了测量能力可接受的标准。但是,精度下降的仪器在可靠性工程中很常见。这使PIT值不足。在这种情况下,提出了一种修改后的指标PIT *来判断量规能力及其估算器,以便仅测量一次零件且仅使用一台仪器的情况。 (18个参考)