首页> 外文期刊>The Journal of Prosthetic Dentistry >Clinical performance and radiographic evaluation of a novel single-piece implant in a private practice over a mean of seventeen months.
【24h】

Clinical performance and radiographic evaluation of a novel single-piece implant in a private practice over a mean of seventeen months.

机译:在私人执业期间平均十七个月,对新型单件式植入物的临床表现和影像学评估。

获取原文
获取原文并翻译 | 示例
           

摘要

STATEMENT OF PROBLEM: A novel 1-piece implant is designed to provide for stable soft tissue, immediate function, and immediate placement in fresh extraction sockets. The purported advantages include less discomfort for the patient, shorter procedure time, and a reduced number of visits as compared to conventional procedures. Clinical documentation is needed to determine whether these advantages can be realized. PURPOSE: The aim of this study was to evaluate the clinical performance and early bone remodeling of the novel 1-piece implant in 1 private general practice. The research hypothesis was that it is possible to achieve similar clinical results using a 1-piece implant instead of the conventional 2-piece implant system with a simpler and more patient-pleasing protocol. MATERIAL AND METHODS: Ninety-two implants, restoring both single teeth and partially edentulous situations, in 58 consecutively treated patients (35 women and 23 men, between the ages of 21 and 78), were included. Retrospective data on implant position, implant size, bone quality, and baseline radiographs was obtained from patient records, and 46 patients attended an additional prospective follow-up visit at 12 months or longer. Data were analyzed with descriptive statistics. RESULTS: No implant failure occurred. After a mean of 17 months the average bone level was positioned at the first thread, which is in accordance with observations for other implants. In general, healthy soft tissue and favorable esthetic outcomes were observed. CONCLUSIONS: The favorable implant survival rate and stable bone level together with the esthetic and soft tissue outcomes indicate that this novel 1-piece implant is a viable treatment option. The data support the hypothesis that it is possible to achieve similar clinical results using a 1-piece implant system instead of a 2-piece implant system with a simpler and more patient-pleasing clinical protocol.
机译:问题陈述:一种新颖的1件式植入物旨在提供稳定的软组织,即时功能以及立即放置在新鲜拔牙窝中的功能。据称,与常规手术相比,其优点包括对患者的不舒适感,较短的手术时间以及更少的就诊次数。需要临床文档来确定是否可以实现这些优势。目的:本研究的目的是在一种私人通用实践中评估新型1件式植入物的临床性能和早期骨重塑。研究假设是,使用一件式植入物代替传统的一件式植入物系统,并以更简单,更令人愉悦的治疗方案,可以获得相似的临床结果。材料与方法:纳入了58例接受连续治疗的患者(35例女性和23例男性,年龄在21至78岁之间)中的92个植入物,这些植入物既可以修复单颗牙齿又可以修复部分缺牙的情况。从患者记录中获得了有关植入物位置,植入物大小,骨质量和基线X线照片的回顾性数据,其中46例患者在12个月或更长时间接受了额外的前瞻性随访。使用描述性统计数据分析数据。结果:没有发生植入失败。平均17个月后,将平均骨水平定位在第一根螺纹处,这与其他植入物的观察结果一致。通常,观察到健康的软组织和良好的美学效果。结论:良好的植入物存活率和稳定的骨水平以及美观和柔软的组织结局表明,这种新颖的1件式植入物是一种可行的治疗选择。数据支持这样的假设,即使用一件式植入系统代替一件具有更简单,更令人愉悦的临床协议的两件式植入系统,可以获得相似的临床结果。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号