首页> 外文期刊>The Journal of Prosthetic Dentistry >Analysis of three-dimensional distortion of two impression materials in the transfer of dental implants.
【24h】

Analysis of three-dimensional distortion of two impression materials in the transfer of dental implants.

机译:牙科植入物转移过程中两种印模材料的三维变形分析。

获取原文
获取原文并翻译 | 示例
           

摘要

STATEMENT OF PROBLEM: In dental implant restorations, a lack of passivity may be associated with mechanical failure. Passivity can be compromised during impression making. PURPOSE: The purpose of this study was to compare the distortion of mechanically mixed polyether and hydrophilic addition silicone impression materials, and to evaluate the effect of intercoping distance on distortion. MATERIAL AND METHODS: Twenty impressions (10 polyether and 10 silicone) were made from a single mandibular definitive cast with 5 abutment analogs using standardized laboratory and technique protocols. The direct impression technique and mechanical mixing were used. A precision measuring machine established spatial coordinates of the impression copings in 3 dimensions, with the operator blinded to materials. Linear distances (concentricity) and angular inclinations (perpendicularity, parallelism) were calculated to measure impression distortion relative to the positions/angulations of the implants in the definitive cast. Distortion differences between materials and implant intercoping distances were tested using 2-factor ANOVA with an interaction term. A Bonferroni 2-sided test was used (alpha=.05). RESULTS: No significant difference was found between the impression materials for parallelism (P=.91) and concentricity (P=.85). For perpendicularity, the silicone material had an average of 0.643 degrees less distortion (P=.004). With respect to intercoping distances, no significant differences were found for perpendicularity (P=.234), parallelism (P=.114), or concentricity (P=.346). An interaction term for material and coping distance was not significant. CONCLUSIONS: Hydrophilic addition silicone and polyether impression materials have similar distortion effects for transfer procedures when using the direct impression technique and machine mixing. Silicone demonstrated superiority for perpendicularity distortion, though of a magnitude unlikely to have clinical significance.
机译:问题陈述:在牙种植体修复中,钝性不足可能与机械故障有关。在进行印模时,被动性可能会受到影响。目的:本研究的目的是比较机械混合的聚醚和亲水性加成硅酮印模材料的变形,并评估套接距离对变形的影响。材料和方法:使用标准化的实验室和技术规程,用5个基台类似物从单个下颌定型铸模制作20个印模(10个聚醚和10个硅酮)。使用直接压印技术和机械混合。一台精密的测量机在3个维度上建立了印模顶盖的空间坐标,操作员对材料不了解。计算线性距离(同心度)和角度倾斜度(垂直度,平行度)以测量相对于确定型腔中植入物的位置/角度的压痕变形。使用带有交互作用项的2因子ANOVA测试材料之间的畸变差异和植入物套合距离。使用Bonferroni 2面测试(alpha = .05)。结果:印模材料的平行度(P = .91)和同心度(P = .85)之间没有显着差异。对于垂直度,有机硅材料的变形平均少0.643度(P = .004)。关于套接距离,在垂直度(P = .234),平行度(P = .114)或同心度(P = .346)方面没有发现显着差异。物质和应对距离的相互作用项并不重要。结论:使用直接压印技术和机器混合时,亲水性加成硅酮和聚醚压印材料在转印过程中具有相似的变形效果。有机硅对垂直度失真具有优越性,尽管其幅度不太可能具有临床意义。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号