The single-stage equilibrium aqueous two-phase extraction (ATPE) of human antibodies from a Chinese hamster ovary (CHO) cells supernatant was investigated. The performance of polyethylene glycol 3350 (PEG 3350)/phosphate aqueous two-phase systems (ATPS) was evaluated by studying several experimental conditions, such as pH, ionic strength, volume ratio and initial antibody concentration in the feed stock. The conditions that favoured the extraction of human immunoglobulin G (IgG) were low pH values, high NaCl concentration and high volume ratios. The percentage of contaminants removal did not depend on the pH value and NaCl concentration, increasing, however, as the volume ratio decreased. About 66% of total contaminants were removed when a volume ratio of 0.4 was used. The multi-stage equilibrium ATPE was also investigated by simulating a four stages cross-current operation in test tubes. According to the IgG equilibrium curves and respective McCabe Thiele diagrams, a predicted optimised scheme of a counter-current multi-stage ATPE was described. An IgG recovery yield of 89% and a protein purity of 75% can be achieved using a PEG/phosphate ATPS containing 10% (w/w) NaCl, five stages and a volume ratio of 0.4. This represents significant improvements in the recovery yield and purity when compared to a single-stage trial performed at the same experimental conditions, where a 61% recovery yield and 55% protein purity were attained. Based on the CHO cells supernatant components equilibrium curves, it was observed that IgG can be completely purified from the higher molecular weight (MW) components and partially purified from the lower MW components.
机译:研究了中国仓鼠卵巢(CHO)细胞上清液中人抗体的单阶段平衡水两相萃取(ATPE)。通过研究几种实验条件,例如pH,离子强度,体积比和原料中的初始抗体浓度,对聚乙二醇3350(PEG 3350)/磷酸盐水溶液两相系统(ATPS)的性能进行了评估。有利于提取人免疫球蛋白G(IgG)的条件是低pH值,高NaCl浓度和高体积比。污染物去除的百分比不取决于pH值和NaCl浓度,但是随着体积比的减小而增加。当使用0.4的体积比时,去除了大约66%的总污染物。还通过模拟试管中的四级交叉电流操作来研究多级平衡ATPE。根据IgG平衡曲线和各自的McCabe Thiele图,描述了预测的逆流多级ATPE优化方案。使用含有10%(w / w)NaCl,五个阶段,体积比为0.4的PEG /磷酸盐ATPS可以实现89%的IgG回收率和75%的蛋白质纯度。与在相同实验条件下进行的单阶段试验相比,这代表了回收率和纯度的显着提高,在相同的实验条件下,回收率和蛋白质纯度均达到了61%。基于CHO细胞上清液组分平衡曲线,观察到IgG可以从较高分子量(MW)组分完全纯化,而可以从较低MW组分部分纯化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号