首页> 外文期刊>Journal of Bionanoscience >Electrochemical Sensing of Histidine Based on the Copper Germanate Nanowires Modified Electrode
【24h】

Electrochemical Sensing of Histidine Based on the Copper Germanate Nanowires Modified Electrode

机译:基于锗酸铜纳米线修饰电极的组氨酸的电化学传感

获取原文
获取原文并翻译 | 示例
           

摘要

The electrochemical sensing behaviors of the L-histidine have been analyzed based on the copper germanate nanowires modified glassy carbon electrode by cyclic voltammetry method. The copper germanate nanowires can be attached firmly to the surface of bare glassy carbon electrode. The semi-reversible cyclic voltammetry peaks are located at +0.35 V and -0.51 V, respectively. With the modification of the copper germanate nanowires, the detection limit of 1.3 μM L-histidine and linear relationship over 0.005 to 2 mM are obtained. The copper germanate nanowires modified glassy carbon electrode exhibits good stability and reproducibility.
机译:基于循环伏安法,基于锗酸铜纳米线修饰的玻碳电极对L-组氨酸的电化学传感行为进行了分析。锗酸铜纳米线可以牢固地连接到裸露的玻璃碳电极的表面。半可逆循环伏安法峰分别位于+0.35 V和-0.51V。通过对锗酸铜纳米线的改性,获得了1.3μML-组氨酸的检测限和0.005至2 mM的线性关系。锗酸铜纳米线修饰的玻碳电极表现出良好的稳定性和可重复性。