首页> 外文期刊>Journal of cardiac surgery. >The patency of sequential and individual saphenous vein grafts after off-pump coronary artery bypass grafting.
【24h】

The patency of sequential and individual saphenous vein grafts after off-pump coronary artery bypass grafting.

机译:非体外循环冠状动脉搭桥术后顺序和单个大隐静脉移植的通畅性。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: The impact of the grafting techniques (individual or sequential grafts) on the graft patency of off-pump coronary artery bypass grafting (OPCAB) has not been reported. The mid-term patency rates for individual and sequential saphenous vein grafts (SVGs) as coronary bypass conduits of OPCAB were compared. METHODS: A total of 714 distal coronary anastomoses on 448 SVGs were assessed using a 64-multislice computed tomography in 398 patients at an average of 26.4 +/- 23.6 months (three months to five years) after an OPCAB procedure. The blood flow of grafts in the proximal segment of individual and sequential SVGs was also compared. RESULTS: The overall patency of sequential SVGs (95.9%) was significantly superior to individual ones (90.6%, p = 0.022). The anastomoses on the sequential conduits had better patency (95.1% vs. 90.1%, p = 0.013). The patency of side-to-side anastomoses (97%) was better than that of end-to-side anastomoses (93.1%) and also better than that of the individual end-to-side anastomoses (90.1%, p = 0.002, p = 0.041). No significant difference was observed between the two approaches in regard to the three major coronary systems; however, anastomoses on sequential grafts had superior patency to those on individual grafts in the right coronary system (p = 0.008). The blood flows of double and triple sequential SVGs were significantly higher than those of individual ones (p < 0.001, p = 0.048, respectively). CONCLUSIONS: The mid-term patency of a sequential SVG conduit after OPCAB is excellent and generally superior to that of an individual one.
机译:背景:尚未报道移植技术(单个或顺序移植)对非体外循环冠状动脉搭桥术(OPCAB)移植通畅的影响。比较了作为OPCAB冠状动脉旁路导管的单个和连续大隐静脉移植物(SVG)的中期通畅率。方法:采用OPCAB手术后,平均398个患者在26.4 +/- 23.6个月(3个月至5年)的26.4 +/- 23.6个月(3个月至5年)内使用64层计算机体层摄影术评估了448个SVG上总共714例远端冠状动脉吻合。还比较了单个和连续SVG近端部分的移植物血流量。结果:顺序性SVG的总体通畅度(95.9%)明显优于单个SVG(90.6%,p = 0.022)。顺序导管上的吻合口通畅性更好(95.1%比90.1%,p = 0.013)。侧向吻合术的通畅度(97%)优于端侧吻合术的通畅度(93.1%),也比单个端侧吻合术的通畅度(90.1%,p = 0.002, p = 0.041)。在三种主要冠状动脉系统方面,两种方法之间没有观察到显着差异。但是,在右冠状动脉系统中,顺序移植的吻合口通畅性优于单个移植的吻合口(p = 0.008)。两次和三次连续SVG的血流量显着高于单个SVG(分别为p <0.001,p = 0.048)。结论:OPCAB术后顺序性SVG导管的中期通畅性极好,并且通常优于单个导管。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号