首页> 外文期刊>Journal of cardiac surgery. >A Technique for Avoiding Patient-Prosthesis Mismatch in the Small Aortic Root
【24h】

A Technique for Avoiding Patient-Prosthesis Mismatch in the Small Aortic Root

机译:避免小主动脉根部患者假体不匹配的技术

获取原文
获取原文并翻译 | 示例
           

摘要

In the small aortic root, extremely weakened tissue and extensive calcification predispose toward the implantation of small prostheses, anastomotic bleeding, and paravalvular leaks. We describe a procedure in which a homemade composite mechanical prosthesis-conduit is implanted in a supra-annular position in two patients with a small aortic root. This technique facilitates the placement of a larger prosthesis, thus avoiding patient-prosthesis mismatch. doi: 10.1111/jocs.12741 (J Card Surg 2016;31:309-310)
机译:在小主动脉根中,组织的极度弱化和广泛的钙化易于植入小假体,吻合口出血和瓣周漏。我们描述了一种程序,其中将自制的复合机械假体导管植入两名主动脉根部较小的患者的瓣环上位置。此技术有助于放置较大的假体,从而避免患者假体不匹配。 doi:10.1111 / jocs.12741(J Card Surg 2016; 31:309-310)