摘要

OBJECTIVE: To investigate the reliability and validity of a clinical evaluation method for the assessment of the dynamic postural control in patients with chronic ankle instability (CAI). DESIGN: Cross-sectional study. SETTING: All tests were conducted at the practice room of the Physical Therapy Department. PARTICIPANTS: Twenty-nine healthy subjects and 29 patients with CAI were selected. INTERVENTIONS: Participants performed twice a multiple hop test within a 1-week time interval. Subjects hopped on 10 different tape markers while trying to avoid any postural correction. MAIN OUTCOME MEASURES: The number and type of balance errors were documented by analyzing the digital video images. RESULTS: Test-retest reliability of the number of balance errors was excellent in patients (intraclass correlation coefficient, ICC = 0.83; standard errors of measurement = 2.6) and moderate in healthy subjects (ICC = 0.64; standard errors of measurement = 2.8). The intra-observer and inter-observer reliability was excellent (ICC > 0.90). Both for the test (P = 0.000) and for the retest (P = 0.000), the number of balance errors in patients was significantly higher (17.9 +/- 6.6) when compared with healthy subjects (10.9 +/- 4.6). On both test occasions, patients with CAI used significantly more a change-in-support strategy (test: P = 0.000; retest: P = 0.000). The number of balance errors was significantly correlated with the time needed to perform the test (r = 0.60; P = 0.000) and the perceived difficulty of the hop test as rated on a visual analogue scale (r = 0.44; P = 0.014). CONCLUSIONS: The multiple hop test is a reliable and valid test for detecting an impaired dynamic postural control in patients with CAI.
机译:目的:探讨临床评估方法对慢性踝关节不稳(CAI)患者动态姿势控制评估的可靠性和有效性。设计:横断面研究。地点:所有测试均在理疗科的练习室进行。参与者:选择了29名健康受试者和29名CAI患者。干预措施:参与者在1周的时间间隔内进行了两次多跳测试。在试图避免姿势矫正的同时,受试者跳了10种不同的胶带标记。主要观察指标:通过分析数字视频图像记录平衡差的数量和类型。结果:患者的平衡误差数目的重测信度极好(组内相关系数,ICC = 0.83;标准测量误差= 2.6),在健康受试者中中等(ICC = 0.64;标准测量误差= 2.8)。观察者内部和观察者之间的可靠性极佳(ICC> 0.90)。对于测试(P = 0.000)和重新测试(P = 0.000),与健康受试者(10.9 +/- 4.6)相比,患者的平衡误差数量明显更高(17.9 +/- 6.6)。在这两个测试场合中,CAI患者都使用了更多的支持改变策略(测试:P = 0.000;重新测试:P = 0.000)。平衡误差的数量与执行测试所需的时间(r = 0.60; P = 0.000)和以视觉模拟量表进行评分的跳跃测试的感知难度(r = 0.44; P = 0.014)显着相关。结论:多跳测试是检测CAI患者动态姿势控制受损的可靠且有效的测试。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号